Controllers for Teddington Air Curtain systems
Intuitive and user-friendly
Air Curtain systems must switch on when they are needed. That's why we offer customized control systems for individual requirements on site. The most important thing: installation and operation are intuitive and user-friendly.
- Controllers specifically for Shop & Business or industrial applications
- Can be integrated into the existing building management system (BMS)
- Multi-master solutions – one control panel for several independently controlled Air Curtain units
- Fully automatic solutions – once set, the system runs automatically all year round depending on the temperatures
Controllers for our Shop & Business and Design Air Curtains
Broad controller portfolio
Modern and fast-responding touchscreen for our TCX controller
Controllers for the basic functions of the Air Curtains (TSC 5 and TSC 3-E)
Integration into Modbus or BACnet networks via the TCX Ethernet module with control panel
Full functionality via Modbus RTU without control panel
Ethernet module (TCX)
TCX-E
TCX Lite
TSC 5
TSC 3-E
Functions of the Shop & Business controllers
TCX | TCX-E | TCX Lite | TSC 5 | TSC 3-E | |
Heating medium | Water heater | Electric heater | Water heater | Water heater | Electric heater |
Air volume control | 5-stage / stepless | 3-stage / stepless | 5-stage / stepless | 5-stage / stepless | 3-stage / stepless |
Key lock | ● | ● | ● | X | X |
External release | ● | ● | ● | ● | ● |
Summer / winter function | ● | ● | ● | ● | X |
Manual / automatic function | ● | ● | ● | ● | ● |
Room thermostat | ● | X | X | ● | ● |
Room sensor | ● | X | X | X | X |
Potential-free operating and fault message | ● | ●*2 | ● | ●*1 | ●*1 |
Integrated weekly timer | ● | ● | X | ● | ● |
After-Run function | ● | ● | ● | ● | ● |
Filter monitoring | ● | X | X | X | X |
Operating hours counter | ● | X | X | X | X |
Fault memory | ● | ● | ● | X | X |
Speed control from the BMS | ● | ● | ● | ● | ● |
Electrical discharge temperature control | ● | X | X | X | X |
Expandable with Ethernet module | ● | ● | X | X | X |
Multi-master function | ● | ● | X | X | X |
Menu languages | 10 | 10 | 10 | - | - |
*2 = potential-free operating message only
*3 = potential-free operating and fault message only for EC motors, 0 - 10 V signal for AC motors
The most important functions explained (click on the “+” to open the information):
The device is enabled by a BMS via external enable. The external release takes place via a potential-free contact.
It is easy to switch between summer and winter mode via the control unit.
In summer mode, all connected heating valves are closed. The air curtain then operates in ambient mode.
In winter mode, shut-off valves are opened and control valves resume normal operation. The discharged air is heated accordingly.
It is easy to switch between manual and automatic mode via the control unit.
In manual mode, the Air Curtain system runs independently of automatic signals (e.g. door contact).
In automatic mode, the Air Curtain system is switched on or off by external signals.
The Air Curtain system can be set to operate depending on the room temperature.
The control unit continuously emits a status message via potential-free signals. The operating or fault message can be processed by the BMS to monitor the Air Curtain system.
The Air Curtain system is switched on and off depending on stored switching times.
To avoid constantly switching the Air Curtain system on and off, a after-run time can be set to allow the unit to continue running for a short time after the door is closed.
For automatic mode, a speed for the fans in the Air Curtain system can be specified by the BMS. This is done via a 0-10 V signal (or 4-20 mA signal with TCX).
With the optional Ethernet module for the TCX control unit, all essential device functions can be controlled via the BMS. The Modbus and BACnet (TCP/IP) protocols are available for this purpose.
One control panel can be used for several independently operating Air Curtain systems. A lean solution for large entrance areas with several independent Air Curtains.
TSDM 5 (400V)
TCI-230 (230V)
Controls for our industrial air curtains
Robust and durable
IP54 as standard for use even in damp environments
5 standard functional scopes (S, M, L, XL, XXL) for every requirement (see table for function overview)
Standard functions of the TSDM 5 and TCI-230 industrial controllers
S | M | L | XL | XXL | |
Control cabinet with protection class IP54 | ● | ● | ● | ● | ● |
Mounting brackets | ● | ● | ● | ● | ● |
Full motor protection | ● | ● | ● | ● | ● |
Manual / automatic function | ● | ● | ● | ● | ● |
Repair switch | ● | ● | ● | ● | ● |
Operating and fault signal | ●*3 | ● | ● | ● | ● |
ext. Release reset | X | ● | ● | ● | ● |
Summer / winter changeover | X | X | ● | ● | ● |
Frost protection function | X | X | ● | ● | ● |
Fixed base load level | X | ● | X | X | X |
Adjustable base load level | X | X | ● | ● | ● |
After-run function automatic contact | X | ● | ● | ● | ● |
Integrated weekly timer | X | X | X | ● | ● |
Fault memory | X | X | X | ● | ● |
Speed control from the BMS | X | X | X | ● | ● |
Ethernet module (Modbus, BACnet) | X | X | X | X | ● |
*3 Indicator lights only
The most important functions explained (click on the “+” to open the information):
The device is enabled by a BMS via external enable. The external release takes place via a potential-free contact.
It is easy to switch between summer and winter mode via the control unit.
In summer mode, all connected heating valves are closed. The air curtain then operates in ambient mode.
In winter mode, shut-off valves are opened and control valves resume normal operation. The discharged air is heated accordingly.
It is easy to switch between manual and automatic mode via the control unit.
In manual mode, the Air Curtain system runs independently of automatic signals (e.g. door contact).
In automatic mode, the Air Curtain system is switched on or off by external signals.
The Air Curtain system can be set to operate depending on the room temperature.
The control unit continuously emits a status message via potential-free signals. The operating or fault message can be processed by the BMS to monitor the Air Curtain system.
The Air Curtain system is switched on and off depending on stored switching times.
To avoid constantly switching the Air Curtain system on and off, a after-run time can be set to allow the unit to continue running for a short time after the door is closed.
For automatic mode, a speed for the fans in the Air Curtain system can be specified by the BMS. This is done via a 0-10 V signal (or 4-20 mA signal with TCX).
With the optional Ethernet module for the TCX control unit, all essential device functions can be controlled via the BMS. The Modbus and BACnet (TCP/IP) protocols are available for this purpose.
One control panel can be used for several independently operating Air Curtain systems. A lean solution for large entrance areas with several independent Air Curtains.
We offer a wide range of accessories for our Air Curtain systems
Get in touch with us!
Please fill out the contact form. Fields marked with * are mandatory.
We will get in touch with you as soon as possible.
- Air Discharge System: CONVERGO® pressure chamber nozzle system
- Air Discharge Range:
- Mounting position:
- Area of application:
- Shape:
- Heating type:
- Sound insulation:
- Unit Length: Unit length made to measure
- Fan technology: AC